Compare the monitoring models
Now
Sense
Features
Monitoring
Particulate matter (PM1, PM2.5, PM10)
Carbon dioxide
Volatile organic compounds
Atmospheric pressure
Temperature
Humidity
Remediation
No
Monitoring
Particulate matter (PM1, PM2.5, PM10)
Carbon dioxide
Volatile organic compounds
Atmospheric pressure
Temperature
Humidity
Radon
Remediation
No
Technical details
Dimensions
125 x 125 x 59 mm
Weight
170g
Materials
ABS Plastic,
Anti-vibration rubber feet
Production
Italy
Status indicator
Multicolored LED
Connectivity
2.4 GHz Wi-Fi WPA2 – PSK
Power source
Input 100 – 240V A.C., 50 – 60 Hz;
output 6 D.C., 0.83 A (5W)
Operating temperature
From -5 °C to +40 °C
Usage humidity
From 0% to 80%
Use
Internal use
Contents of the package
Radoff Now, power supply, quick guide
Compatibility
Alexa
Dimensions
125 x 125 x 147 mm
Weight
570g
Materials
ABS plastic,
Anti-vibration rubber feet
Production
Italy
Status indicator
Multicolored LED
Connectivity
2.4 GHz Wi-Fi WPA2 – PSK
Power source
Input 100 – 240V A.C., 50 – 60 Hz;
output 6 D.C., 0.83 A (5W)
Operating temperature
From -5 °C to +40 °C
Usage humidity
From 0% to 80%
Use
Internal use
Contents of the package
Radoff Now, power supply, quick guide
Compatibility
Alexa
Sensors
Radon
No
Radon
Active measuring chamber
APPROVED BY INMRI – ENEA
Measurement: 0 Bq/m3 to 20,000 Bq/m3
Accuracy: 0-500 Bq/m3: ± 50 Bq/m3 | 500-1000 Bq/m3: ± 100 Bq/m3 | 1000-5000 Bq/m3: ± 200 Bq/m3 | 5000-20000 Bq/m3: ± 500 Bq/m3
PM
Optical sensor with laser detection
Measurement PM1: 0 µg/m3 to 1000 µg/m3
Measurement PM2.5: 0 µg/m3 to 1000 µg/m3
Measurement PM10: 0 µg/m3 to 1000 µg/m3
Accuracy: ± 15%
CO2
NDIR Sensor (non-dispersive infrared)
Measurement: 400 ppm to 10,000 ppm
Accuracy: ±50 ppM
VOC
MOx Technology: Metal Oxide Gas Sensor
Measurement: 0 ppm to 1000 ppm
Accuracy: ±50 ppm
Temperature
Measurement: -40°C to 100°C
Accuracy: ± 1°C
Humidity
Measure: 0% to 100%
Accuracy: ± 10% RH
Atmospheric pressure
Measurement: 300 to 1100 hPa
Accuracy: ± 9 Pa
PM
Optical sensor with laser detection
Measurement PM1: 0 µg/m3 to 1000 µg/m3
Measurement PM2.5: 0 µg/m3 to 1000 µg/m3
Measurement PM10: 0 µg/m3 to 1000 µg/m3
Accuracy: ± 15%
CO2
NDIR Sensor (non-dispersive infrared)
Measurement: 400 ppm to 10,000 ppm
Accuracy: ±50 ppM
VOC
MOx Technology: Metal Oxide Gas Sensor
Measurement: 0 ppm to 1000 ppm
Accuracy: ±50 ppm
Temperature
Measurement: -40°C to 100°C
Accuracy: ± 1°C
Humidity
Measure: 0% to 100%
Accuracy: ± 10% RH
Atmospheric pressure
Measurement: 300 to 1100 hPa
Accuracy: ± 9 Pa